Parker TPD-M Drive Fault Codes & Diagnostic Guide
Complete multi-axis fault code reference directory, trip alarm causes, and step-by-step troubleshooting procedures for the Parker TPD-M modular servo drive series. Search or filter through the complete diagnostic directory below.
Current / Power
Up to 20 kVA (2A – 30A per Axis)
Supply Voltage
325 – 680 VDC (Common Bus)
Control Modes
Multi-Axis Position, Speed & Torque
Operator Interface
MotionWiz Software & 7-Segment LED
Complete Parker TPD-M Drive Fault Code Directory
Use the search box in the table below to quickly find your alarm code (e.g., type 1 for Overvoltage, 3 for Overcurrent, Feedback, or Resolver).
| Fault Code and Meaning | Cause and Remedy |
|---|---|
| 0 No alarm | Cause: Standard operation status. Remedy:
|
| 1 DC circuit overvoltage | Cause: Voltage on DC bus is too high. Remedy:
|
| 2 DC circuit undervoltage | Cause: Voltage on DC bus is too low. Remedy:
|
| 3 Overcurrent | Cause: Current exceeds limits, potential short circuit. Remedy:
|
| 4 FBK error (resolver or encoder) | Cause: Feedback device signal failure. Remedy:
|
| 5 PTC motor alarm | Cause: Motor temperature sensor issue. Remedy:
|
| 6 Power module overtemperature | Cause: Drive module is overheating. Remedy:
|
| 7 External alarm | Cause: Triggered by external input. Remedy:
|
| 8 Auxiliary alarm | Cause: Triggered by auxiliary condition. Remedy:
|
| 10 (*) Check sum pico-PLC | Cause: Parameter/Programming checksum error. Remedy:
|
| 11 (*) Check sum parameters | Cause: Parameter checksum error. Remedy:
|
| 12 Signature firmware | Cause: The signature is not installed. Remedy:
|
| 13 CANopen DS402 abort connection | Cause: Communication abort. Remedy:
|
| 15 Default parameters | Cause: Parameters reset or corrupt. Remedy:
|
| 16 CANopen missing sync | Cause: Synchronization signal lost. Remedy:
|
| 17 (**) Hardware alarm | Cause: Internal hardware damage or fault. Remedy:
|
| 22 Ambient over temperature | Cause: The ambient temperature in the electric cabinet is excessive (>45°C). Remedy:
|
| 24 PSU alarm | Cause: Power Supply Unit issue. Remedy:
|
| 25 (**) Speed loop FBK initialization error | Cause: Issue during feedback initialization. Remedy:
|
| 27 Overloads digital outputs | Cause: Excessive load on outputs. Remedy:
|
| 31 Communication error | Cause: Field-bus issue. Remedy:
|
| TripP.x Hardware broken | Cause: Hardware failure (x is a number). Remedy:
|
| I²T Current limit (I²T) | Cause: Drive entered I²T mode due to overload (current required > current supplied). Remedy:
|
| Pr23: 0 / Pr24: 4 Serial line error | Cause: Connection issue. Remedy:
|
| Pr23: 0 / Pr24: 5 Power supply not 3-phases | Cause: Phase loss. Remedy:
|
| Pr23: 3 / Pr24: 1 Hardware from FPGA | Cause: Internal hardware signal. Remedy:
|
| Pr23: 3 / Pr24: 2 I2t maximum reached | Cause: Overload threshold reached. Remedy:
|
| Pr23: 3 / Pr24: 3 Stall status of V/F | Cause: Motor stalled in V/F mode. Remedy:
|
| Pr23: 17 / Pr24: 1 Different number of axes | Cause: Configuration mismatch. Remedy:
|
| Pr23: 17 / Pr24: 2 Number of axes configuration | Cause: Configuration error. Remedy:
|
| Pr23: 17 / Pr24: 3 Feedback configuration | Cause: Configuration error. Remedy:
|
| Pr23: 17 / Pr24: 4 ADC on FPGA error | Cause: Conversion error on FPGA. Remedy:
|
| Pr23: 17 / Pr24: 5 EEprom error | Cause: Memory failure. Remedy:
|
| Pr23: 17 / Pr24: 6 FPGA fault | Cause: Processor fault. Remedy:
|
| Pr23: 17 / Pr24: 7 EEprom checksum error | Cause: Memory data corruption. Remedy:
|
| Pr23: 17 / Pr24: 8 NIOS SDRAM checksum error | Cause: RAM data corruption. Remedy:
|
| Pr23: 17 / Pr24: 9 NIOS RAM checksum error | Cause: RAM data corruption. Remedy:
|
| Pr23: 17 / Pr24: 10 FPGA blocked | Cause: Processor freeze. Remedy:
|
| Pr23: 17 / Pr24: 11 FPGA watchdog alarm | Cause: Watchdog timer expiration. Remedy:
|
| Pr23: 17 / Pr24: 12 NIOS watchdog alarm | Cause: Watchdog timer expiration. Remedy:
|
How to Clear & Reset Parker TPD-M Drive Faults
- MotionWiz PC Software: Connect your PC via the USB or front diagnostic serial port, launch the Parker MotionWiz configuration utility, navigate to the tripped axis diagnostic page, and execute the “Fault Reset” command.
- Fieldbus Network Reset: Toggle Bit 7 (Fault Reset) in the standard CiA 402 / DS402 Control Word from logic `0` to logic `1` across your EtherCAT (CoE), CANopen, or PROFINET network interface.
- Digital Input Reset: If programmed via parameter configuration or internal PLC logic on the digital I/O connector (X12/X13), pulse the assigned digital input terminal from 0V to 24V DC to clear latched faults.
- Internal PLC Bit: If using internal motion code, toggle the system reset command bit (e.g., bit
b99.12) within the application script to acknowledge active axis alarms. - Common DC Bus Power Cycle: Power down the main AC supply feeding the common DC bus power supply module. Wait at least 5 to 10 minutes for all shared DC bus discharge lamps to extinguish completely before restoring mains power.
⚠️ High-Voltage Electrical Safety Warning:
The Parker TPD-M operates on a centralized high-voltage DC bus system (325–680 VDC). Extremely lethal electrical energy remains stored across shared capacitor banks after switching off AC line power. Always measure with a calibrated multimeter to verify DC voltage is strictly below 50VDC across the DC bus bars (+BUS and -BUS) before inspecting motor power leads, feedback connectors, or replacing axis modules.