Mitsubishi Electric Drives Fault Codes & Troubleshooting

Technical diagnostic reference for Mitsubishi Electric FREQROL AC variable frequency inverters, regenerative converters, and MELSERVO high-precision motion systems. Select your drive model series below to access parameter checks, trip code descriptions, and physical test procedures.

24 Inverter & Power Series 5 MELSERVO Systems Real Sensorless Vector Control

Mitsubishi FREQROL Inverters & Power Converters

24 Models
FR-A800 →

Flagship Premium Inverter with Real Sensorless Vector & Full Closed-Loop Vector Control

FR-F800 →

Advanced Energy-Saving Drive for Fans, Pumps, Blowers & Multi-Pump Macro Control

FR-E800 →

Next-Gen Compact Multi-Protocol Inverter (Dual Ethernet: CC-Link IE, Modbus/TCP, PROFINET)

FR-E700 →

Popular All-Round High-Function Micro Inverter with Integrated USB & RS-485

FR-D700 →

Standard Compact Micro Drive with Spring Clamp Terminals & Safe Stop Function

FR-CS80 →

Cost-Effective World Smallest Class Compact Micro Inverter for Basic Machines

FR-A700 →

High-Performance Industrial Inverter with Sensorless Vector & Torque Control

FR-A701 →

Integrated Power Regeneration Inverter for Cranes, Hoists & Elevators

FR-F700 →

Dedicated Energy-Saving Inverter for Variable Torque Fan and Pump Loads

FR-F700P →

Optimum Excitation Control HVAC Drive for Facility Pumps & Air Handlers

FR-F700PJ →

Compact Eco-Mode Inverter with Filter Pack for Fan and Pump Optimization

FR-D700G →

Enhanced Safety Global Inverter Model with STO Safe Stop Certification

FR-XC →

Multi-Function Power Regeneration & Low-Harmonic Common DC Bus Converter Box

FR-A500 →

Classic Heavy-Duty Sensorless Vector Inverter Platform (Advanced Magnetic Flux)

FR-E500 →

Classic High-Function Compact Micro Drive with Dynamic Braking Circuit

FR-F500 →

Classic High-Capacity Energy-Saving Inverter for Continuous Pumping Systems

FR-F500L →

Large Capacity Fan & Pump Specialized Variable Torque Controller

FR-F500J →

Compact Fan & Pump Dedicated Drive with Energy-Optimization Features

FR-S500 →

Sub-Compact Simple Inverter with Dial Setting Digital Console

FR-V220E →

High-Precision Full Vector Control Spindle & Elevator Inverter Unit

FR-B3-N(H) 400 →

Pressurised Explosion-Proof Specialized High-Safety Inverter Drive

FR-B-750 →

Flameproof & Hazardous Environment Protected Drive System

MD-AX520 →

Specialized High-Performance Multi-Axis Machine Spindle Controller

MD-CX520 →

Synchronous Multi-Drive Inverter System for Coordinated Web Handling

Mitsubishi MELSERVO AC Servo Systems

5 Models

Most Common Mitsubishi Drive Fault Codes

Diagnostic Quick Reference
Trip Code Trip Name Common Physical Trigger Recommended First Check
E.OC1 Overcurrent during Acceleration Rapid acceleration ramp, short circuit in motor output wiring, or seized mechanical bearing. Increase acceleration time (Pr.7) and verify motor insulation resistance with motor cables uncoupled.
E.OC2 / E.OC3 Overcurrent (Steady / Decel) Sudden load shock during operation or aggressive deceleration forcing excess regenerative current into inverter. Extend deceleration time (Pr.8) and check for intermittent mechanical binding on driven equipment.
E.OV1 / E.OV3 Regenerative Overvoltage Motor regenerative energy during deceleration charging internal DC bus capacitors above trip ceiling (400V/800V). Verify dynamic braking resistor connectivity across PR-PX terminals and increase decel time (Pr.8).
E.THT Inverter Overload Trip Inverter internal output power transistor (IGBT) junction temperature exceeding rated limit due to severe duty cycling. Reduce torque boost (Pr.0), lower PWM carrier frequency (Pr.72), and inspect cabinet ventilation fans.
E.THM Motor Thermal Overload Electronic thermal relay tripped because motor current sustained above rated motor full load amps (FLA). Check motor nameplate current setting in Pr.9 (electronic thermal O/L relay) and check motor cooling fan.
E.GF Output Side Ground Fault Current leakage to ground detected on inverter output terminals (U, V, W) at startup. Check for moisture inside motor conduit box or perform Megger insulation test on motor stator windings.
E.UVT Undervoltage Protection Incoming AC mains line voltage dropped below threshold (approx. 150V for 200V class, 300V for 400V class). Inspect incoming line fuses, measure utility line voltage across R/L1, S/L2, T/L3, and check main contactor.

How to Clear & Reset Mitsubishi VFD Faults

  1. Keypad Reset: Press the STOP / RESET key directly on the operation panel (FR-DU07, FR-DU08, or Parameter Unit FR-PU07).
  2. Control Terminal Reset (RES Terminal): Connect control terminals RES and SD together for at least 0.1 seconds, then disconnect them. (Note: Keep RES-SD disconnected during normal run operation).
  3. FR Configurator2 Software: While connected via USB or PU port, navigate to the diagnostic screen and click the “Fault Reset” button.
  4. Power Cycle: Switch off main circuit power supply, wait until the operation panel display turns off completely (discharge of high-voltage DC bus), then reapply power.
⚠️ High-Voltage Safety Warning: Always verify with a calibrated digital multimeter that intermediate DC bus capacitor voltage measures strictly below 50VDC across terminals (+/P and -/N) before opening terminal covers or touching output terminals U, V, and W on any Mitsubishi drive.