Allen-Bradley Drives Fault Codes & Troubleshooting

Complete diagnostic database for 24 Allen-Bradley PowerFlex & Kinetix drive series. Browse fault codes, alarms, causes, and step-by-step fixes for AC, DC, and servo motion controllers. Select your drive model series below to access parameter checks, root cause analysis, and physical inspection workflows.

11 PowerFlex AC Series 1 PowerFlex DC Series 12 Kinetix Servo Series 24 Total Series

PowerFlex AC Variable Frequency Drives

11 Models

PowerFlex Industrial DC Drives

1 Model

Kinetix Servo & Motion Drives

12 Models

Most Common PowerFlex & Kinetix Fault Codes

Diagnostic Quick Reference
PowerFlex Code Kinetix Code Fault Name Common Root Cause
F012 / F12 FLT M01 / E12 HW OverCurrent Drive hardware peak current limit exceeded due to motor short circuit, bound shaft, or aggressive acceleration.
F005 / F5 FLT M02 / E02 DC Bus OverVoltage DC link voltage exceeded maximum trip threshold; motor regenerative power excessive during deceleration ramp.
F004 / F4 FLT M03 / E03 DC Bus UnderVoltage DC bus voltage dropped below minimum threshold; utility voltage drop, missing incoming line phase, or blown branch fuse.
F013 / F13 FLT M04 / E14 Ground Fault Current path detected from motor output terminals U, V, or W to protective earth; cracked insulation or motor moisture.
F007 / F7 FLT M05 / E06 Motor Overload Continuous motor current exceeded motor rated nameplate Full Load Amps (FLA) according to thermal I²t curve.
F033 / F33 FLT M18 Auto Rstrt Tries Drive unsuccessful in clearing fault condition after reaching maximum programmed automatic restart attempts.

How to Clear & Reset Allen-Bradley Faults

  1. Keypad / HIM Reset: Press the red STOP button directly on the integral keypad or Human Interface Module (HIM) panel.
  2. Studio 5000 / Logix Command: Inside Studio 5000 Logix Designer or Connected Components Workbench (CCW), access the drive properties Add-On Profile (AOP) and click “Clear Fault” (or trigger a Motion Axis Fault Reset MAFR instruction).
  3. Digital Input Pulse: Send a 24VDC pulse to the digital input configured for Clear Fault (e.g., Parameter t062–t068 set to option 1 "Clear Fault" on PowerFlex 520-series).
  4. Power Disconnect Cycle: Remove main 3-phase line AC power, wait 5 minutes until all internal status LEDs and the DC bus charge indicator completely discharge, and reclose the circuit breaker.
⚠️ High-Voltage Safety Warning: Hazardous voltage remains present in the intermediate DC bus capacitors even after the AC line input disconnect has been locked out. Use a certified digital multimeter to verify that the voltage between terminals (+DC) and (-DC) is strictly below 50VDC before inspecting internal components or terminal strips.